For Corner Installations the minimum clearance to combustibles in Table 1 must still be adhered
to. Please refer to Figure 5 and the Clearance to Combustibles table for more information.
In Figure 6, the minimum dimensions of a corner framing scenario is illustrated.
Figure 6 - Corner Installation.
For Raised Installations the minimum clearance to combustibles mentioned in Table 1 must still be
adhered to. Please refer to Figure 5 and the Clearance to Combustibles table for more information.
Furthermore, make special considerations to the Minimum Ceiling height restriction. This value is
taken from the bottom of the appliance—not the floor. Thus, if the unit is installed in a raised con-
figuration then the absolute ceiling height will be
:
This formula is illustrated in Figure 5.
Absolute Minimum Ceiling Height = Min. Ceiling Height + Raised Height
For cabinet installations: It is necessary that the appliance be installed from the rear of the cabi-
net. Simply bend the front Nailing Tabs enough so they clear the cabinet cutout. Once the appli-
ance is positioned through, restore the front Nailing Tabs to their mounting configuration. Once
installed, they should be in front of the face of the cabinet.
Furthermore, it is imperative that the appliance is resting on a secure platform. Consult with the
cabinet manufacturer to ensure that the supporting platform is capable of carrying the load of the
appliance.
NOTE: Additional access to the gas valve and electrical conjunction box is provided. These
cutouts are located at the bottom of the unit. Please refer Figure 1 for the dimensional location.
Corner Installations
Raised Installation
Cabinet Installation Guide